Glycerol (glucokinase format) - Enzymatic assay kit
Reference : K-GCROLGK
        Simple, reliable and accurate method for the measurement of glycerol in beverages, foodstuffs and other material      
            Countries eligible for delivery
            Countries eligible for delivery:
           
            France (except Corsica and overseas departments and territories), Algeria, French overseas departments and territories, French Polynesia, Libyan Arab Jamahiriya, Morocco, Tunisia, Egypt, France (Corsica)		  
    
          Simple, reliable and accurate method for the measurement of glycerol in beverages, foodstuffs and other material
Shipping temperature: ambient
Storage temperature:
- Short term stability: 2-8oC,
- Long term stability: see individual component labels
Assay format: spectrophotometer, microplate, auto-analyser
Detection method: absorbance - 340
Signal response: increase
Linear range: 1,0 to 35 µg of glycerol per assay
Reaction time: ~ 7 min
Detection limit: 0,37 mg/l
Stability: > 2 years under recommended storage condition
Based on use of ADP-glucokinase and increase in absorbance on conversion of NAD+ to NADH.
Novel method
 
        
                Shipping temperature: ambient
Storage temperature:
- Short term stability: 2-8oC,
- Long term stability: see individual component labels
Assay format: spectrophotometer, microplate, auto-analyser
Detection method: absorbance - 340
Signal response: increase
Linear range: 1,0 to 35 µg of glycerol per assay
Reaction time: ~ 7 min
Detection limit: 0,37 mg/l
Stability: > 2 years under recommended storage condition
Based on use of ADP-glucokinase and increase in absorbance on conversion of NAD+ to NADH.
Novel method
- Novel tablet format for increased stability
 - Very competitive price (cost per test)
 - All reagents stable for > 2 years as supplied
 - Very rapid reaction
 - Positive reaction (assay proceeds with an increase in absorbance) - Spreadsheet available
 - Standard included
 - Suitable for manual, microplate and auto-analyser formats
 
          Foodstuffs, beverages and other materials        
        
            
            Data Booklet            
            
            Safety data sheet            
            
            Calculator data            
			
      The attached documents are subject to change. To receive the latest updates, please contact us.
Specifications
| Reference | Packaging | |
|---|---|---|
| K-GCROLGK | 70 tests (manuel/manual), 600 (automate/auto-analyser), 700 (microplaque/microplate) | 
        