New
D-glucose (Megaplex Red Format) - Enzymatic assay kit
Reference : K-MRGLUC
Method with high purity reagents for the measurement of D-glucose in cereal extracts and for use in combination with other enzymatic assay kits.
Countries eligible for delivery
Countries eligible for delivery:
France (except Corsica and overseas departments and territories), Algeria, French overseas departments and territories, French Polynesia, Libyan Arab Jamahiriya, Morocco, Tunisia, Egypt, France (Corsica)
The D-Glucose Assay Kit (Megaplex Red) (K-MRGLUC) is a simple, accurate and user-friendly method for the specific measurement and analysis of D-glucose in foodstuffs, beverages and other materials.
Shipping temperature: ambient
Storage temperature:
Short term stability: 2-8°C,
Long term stability: See individual component labels
Assay format: Spectrophotometer, Microplate, Auto-analyser
Detection method:
(Fluorescence): 530-560 (ex), ~ 590 (em)
(Absorbance): 570
Signal response: increase
Linear range:
(Fluorescence): 0.009-0.18 μg of D-glucose per assay (0.5-10 μM in-assay)
(Absorbance): 0.9-9.0 μg of D-glucose per assay (5-50 μM in-assay)
Reaction Time (min):
(Fluorescence) 30 min
(Absorbance) 30 min
Detection limit: (Fluorescence) 0.09 ug/mL
(Absorbance) 0.25 ug/mL
Stability: > 2 years under recommended storage condition
Shipping temperature: ambient
Storage temperature:
Short term stability: 2-8°C,
Long term stability: See individual component labels
Assay format: Spectrophotometer, Microplate, Auto-analyser
Detection method:
(Fluorescence): 530-560 (ex), ~ 590 (em)
(Absorbance): 570
Signal response: increase
Linear range:
(Fluorescence): 0.009-0.18 μg of D-glucose per assay (0.5-10 μM in-assay)
(Absorbance): 0.9-9.0 μg of D-glucose per assay (5-50 μM in-assay)
Reaction Time (min):
(Fluorescence) 30 min
(Absorbance) 30 min
Detection limit: (Fluorescence) 0.09 ug/mL
(Absorbance) 0.25 ug/mL
Stability: > 2 years under recommended storage condition
- Simple format
- Very competitive price (cost per test)
- Ability to run in fluorescence or absorbance mode
- User friendly - Detailed protocol provided for the creation of calibration curve and the calculation of concentration in fluorescence mode.
- Single point standard for quicker and simpler analysis in absorbance mode.
- Mega-Calc™ software tool is available from our website for hassle-free raw data processing
- Suitable for manual, microplate and auto-analyser formats
- All reagents stable for > 2 years
Food and beverage samples such as wine, beer, fruit juices, soft drinks, milk, jam, dietetic foods, bakery products, candies, fruit and vegetables. Other samples such as tobacco, cosmetics, pharmaceuticals (e.g. infusions), feed, paper (and cardboard) and other materials (e.g. biological cultures, samples, etc.).
Data Booklet
Safety data sheet
Data calculator
The attached documents are subject to change. To receive the latest updates, please contact us.
Specifications
Reference | Packaging | |
---|---|---|
K-MRGLUC | 100 tests (manuel/manual), 400 (automate/auto-analyser), 1000 (microplaque/microplate) |