          The D-Glucose Assay Kit (Megaplex Red) (K-MRGLUC) is a simple, accurate and user-friendly method for the specific measurement and analysis of D-glucose in foodstuffs, beverages and other materials.
Shipping temperature: ambient
Storage temperature:
Short term stability: 2-8°C,
Long term stability: See individual component labels
Assay format: Spectrophotometer, Microplate, Auto-analyser
Detection method:
(Fluorescence): 530-560 (ex), ~ 590 (em)
(Absorbance): 570
Signal response: increase
Linear range:
(Fluorescence): 0.009-0.18 μg of D-glucose per assay (0.5-10 μM in-assay)
(Absorbance): 0.9-9.0 μg of D-glucose per assay (5-50 μM in-assay)
Reaction Time (min):
(Fluorescence) 30 min
(Absorbance) 30 min
Detection limit: (Fluorescence) 0.09 ug/mL
(Absorbance) 0.25 ug/mL
Stability: > 2 years under recommended storage condition
                Shipping temperature: ambient
Storage temperature:
Short term stability: 2-8°C,
Long term stability: See individual component labels
Assay format: Spectrophotometer, Microplate, Auto-analyser
Detection method:
(Fluorescence): 530-560 (ex), ~ 590 (em)
(Absorbance): 570
Signal response: increase
Linear range:
(Fluorescence): 0.009-0.18 μg of D-glucose per assay (0.5-10 μM in-assay)
(Absorbance): 0.9-9.0 μg of D-glucose per assay (5-50 μM in-assay)
Reaction Time (min):
(Fluorescence) 30 min
(Absorbance) 30 min
Detection limit: (Fluorescence) 0.09 ug/mL
(Absorbance) 0.25 ug/mL
Stability: > 2 years under recommended storage condition
- Simple format
 - Very competitive price (cost per test)
 - Ability to run in fluorescence or absorbance mode
 - User friendly - Detailed protocol provided for the creation of calibration curve and the calculation of concentration in fluorescence mode.
 - Single point standard for quicker and simpler analysis in absorbance mode.
 - Mega-Calc™ software tool is available from our website for hassle-free raw data processing
 - Suitable for manual, microplate and auto-analyser formats
 - All reagents stable for > 2 years
 
          Food and beverage samples such as wine, beer, fruit juices, soft drinks, milk, jam, dietetic foods, bakery products, candies, fruit and vegetables. Other samples such as tobacco, cosmetics, pharmaceuticals (e.g. infusions), feed, paper (and cardboard) and other materials (e.g. biological cultures, samples, etc.).        
        
            
            Data Booklet            
            
            Safety data sheet            
            
            Data calculator            
			
      The attached documents are subject to change. To receive the latest updates, please contact us.
Specifications
| Reference | Packaging | |
|---|---|---|
| K-MRGLUC | 100 tests (manuel/manual), 400 (automate/auto-analyser), 1000 (microplaque/microplate) | 
        